free shipping on orders $175+ (excl. discounts, fees and taxes)

0

Certificate Of Analysis (COA) LiBrary

Find your product’s testing results in just a few clicks.
Select your product, match the batch ID, and instantly access the corresponding Certificate of Analysis.

Group 2085667044.png
Group 2085667045.png
Group 2085667046.png
Group 2085667047.png

HOW TO FIND YOUR COA?

A Certificate of Analysis (COA) provides batch-specific verification of a product’s identity, composition, and quality.

  1. Select your carrier type — vials, capsules, liquids, or topical systems.


  2. Identify your product — find your product by name (for example, BPC-157, Cartalax, DSIP).


  3. Match your batch ID — locate the batch ID printed vertically along the side of the product label.


  4. Open the COA — click the matching batch ID button to view, download, or share the certificate of analysis. The COA opens in a new browser tab as a PDF.

ChOOse yOur carrier type

5-Amino-1MQ

Acetic Acid

Adipotide

AICAR

AOD9604

ARA-290

Bacteriostatic Water

BPC-157

BPC-157/TB-500

Cardiogen

Cartalax

Chonluten

CJC-1295

CJC-1295 (with DAC)

CJC-1295 (with DAC) /Ipamorelin Blend

CJC-1295/|pamorelin Blend

Cortagen

DSIP

Epithalon

Follistatin 344

Follistatin-315

FOXO4-DRI

GDF-8

GHK-Cu

GHPR-2

GHPR-6

GLOW (BPC157/GHK-Cu/TB500 Blend)

GLOW PLUS (BPC157/GHK-Cu/TB500/TA-1 Blend)

GLP-1 (C)

GLP-1 (C/S)

GLP-1 (S)

GLP-2 (SU)

GLP-2 (T)

GLP-3 (R)

Glutathione

Gonadorelin

Hexarelin

Hexarelin Acetate

HGH 176-191

Humanin

IGF-1 LR3

Ipamorelin

Kispeptin-10

KLOW

KPV

LC120

LC216 (Lipo-B)

Livagen

LL-37

Melanoten-2

MGF

MOTS-c

N-Acetyl Epithalon

N-Acetyl Selank

N-Acetyl Semax

NAD+

Ovagen

Oxytocin

P-21 (Adamantane)

PEG-MGF

Pinealon

PNC-27

Prostamax

PT-141

Selank

Selank/Semx

Semx

Sermorlin

SLU-PP-332

Snap-8

SS-31

TB-500

Tesmorelin

Thymalin

Thymogen

Thymosin Alpha-1

Thymosin Beta4

Vesugen

Vilon

VIP

5-Amino-1MQ

BAM 15

BPC-157

BPC-157 / TB-500 (Tβ4) Blend

DHX/PNB-0408

Epithalon

GLOW

Ibutamoren

KPV

Methylene Blue

Mots-C

Orforglipron

Regen

SLU-PP-332

TB-500 (Tβ-4)

TESO/NS2330

TUDCA

BPC 157

BPC-157/TB-500

DSIP

Epithalon

GHK-Cu

KPV

LC120

LC216

NAD+

PT141

Selank

SEMX

TB 500

Vocus

System A –Lot PHP-TSA-001

System B –Lot PHP-TSB-001

System C –Lot PHP-TSC-001

System D –Lot PHP-TSD-001

System E –Lot PHP-TSE-001

Why every batch is testeD

Pure Health Peptides does not test its own products. Every Certificate of Analysis you receive from us is issued by an independent third-party laboratory with its own accreditations, its own analytical staff, and its own commercial reputation to protect.

Group 2085666968

Independence eliminates conflict of interest

A supplier that tests its own products has every commercial incentive to report favorably on them. An independent lab has the opposite incentive — its credibility, and therefore its ability to operate, depends on its results being reliable regardless of who pays for the test.

Group 2085666985

Accredited methods deliver reproducible results

The labs we work with operate under recognized analytical chemistry standards using calibrated instrumentation and validated methods. The same sample, tested twice, should yield the same answer.

Group 2085666970

Documentation that travels

A COA from a recognized independent laboratory is documentation a researcher can rely on, present to a peer reviewer, or use as part of a published methods section. A self-issued certificate carries none of that weight.

Frequently asked questions

01 Where is my batch ID printed?

The batch ID is printed vertically along the side of the product label. The same identifier appears on the COA. If your product label is damaged or unreadable, contact us at info@purehealthpeptides.com with a photo of your product and we’ll help locate the matching COA.

All in-distribution batches should appear in the library. If yours doesn’t, the most likely reasons are: (1) the batch is older than the current indexing window, (2) there is a data-entry delay between manufacture and library publication, or (3) the batch ID has been transcribed slightly differently. In all cases, please contact us with a clear photo of your label and we will provide the COA directly.

Yes. When you click your matching batch ID, the COA opens in a new browser tab as a standard PDF. From there you can view, download, save, print, or share the file. The PDF is unwatermarked and unrestricted.

The product page lists the minimum specification — the floor every batch must meet. The COA reports the actual measured result for the specific batch you received, which will typically exceed the specification. A spec of “≥99%” with a result of “99.82%” means your batch is well above the minimum.

Every COA is issued by an independent third-party analytical laboratory. Pure Health Peptides does not perform its own testing. Our primary testing partner is Ethos Analytics, an ISO/IEC 17025-accredited laboratory; earlier COAs in the Library may be issued by BioRegen or other prior testing partners. The lab is identified on each COA. We send samples to the lab, the lab analyzes them and issues the certificate, and we publish those certificates to you unaltered.

Yes. Every Pure Health Peptides product — vials, capsules, liquids, and topical systems — uses the same universal QR code. The QR code points to this COA Library landing page, where you select your carrier type to begin the lookup.

Some batches are filled into multiple presentation sizes from the same production lot. Where this is the case, the size is appended to the batch ID button (e.g. “SYN-030926 (10 mg)” vs “SYN-030926 (5 mg)”) so you can match the exact presentation you received.

Yes. As of May 2026, our standard COA panel includes five tests: identity, purity, quantity, endotoxin, and microbial limits. The first three address the peptide itself — the result of the chemical synthesis step. The last two address the supply chain that delivers the product to your hand, since environmental contamination can theoretically enter through downstream handling, lyophilization, vial filling, storage, or transit. Earlier COAs in the Library may reflect our earlier three-test panel; we preserve those records unchanged because record integrity matters. See “Why we test for endotoxin and microbial limits” above for the full explanation.

Yes. Each COA carries the issuing laboratory’s contact information and a unique COA reference number. You can contact the lab directly to verify that the COA was issued by them.

subscribe to newsletter

Be the first to know about new products & special
offers from Pure Health Peptides!

    Your Cart
    Your cart is emptyReturn to Shop

    Welcome to

    Pure Health Peptides

    All products sold by Pure Health Peptides LLC are intended for laboratory and research purposes only. They are not for human consumption, veterinary use, or medical applications. You must be 21 years or older to purchase. Misuse of these products is strictly prohibited.

    You must be 21 or older to access this site.